XNX Universal Transmitter Technical Manual - Page 155

For XNX UNIVERSAL.

Loading ...
Loading ...
Loading ...
XNX Universal Transmitter
Section 6 - Specications
153
6.4.4 Multi Purpose Detector (MPD)
SimilartotheXNXTransmitter,theMPDpartnumberingsystemdenestheagencyapprovalandthreadtype.Theonlymaterialselection
isStainlessSteel.Foursensorselectionsareavailable.AgencyApprovalsarespecictothe4sensortypes.Ensuretheapprovalof
thespecicsensortypemeetstherequirementsoftheinstallation.
Model Type Port Cong
Installed Sensor Range
(See Section 6.2 for Agency Approvals)
MPD -
q q q q q
AM M25
CB - Catalytic Bead %LEL 1 - Default
UT 3/4” NPT
IF - IR %LEL Flammable 2 to 9 - Future
BT 3/4” NPT
IV - IR Methane 0-5% Vol
IC - R Carbon Dioxide 0-5% Vol
6.4.5 XNX Catalytic Bead and IR Replacement Sensor Cartridges
Sensor
Type
1, 2
Target Gas
Cartridge
Part No
Operating
Pressure
Range
(kPa)
Operating
Humidity
Range (%
RH non-
condensing)
Air
Speed
(m/s)
Maximum
Range
Selectable
Range
3
Increment
Default
Range
Cal Gas Range Cal Gas P/N
Cal Gas
Description
MPD-IC1 Carbon Dioxide 1226-0301 80 - 110 see footnote 4 0 - 6 5.00 %Vol 1.00 to 5.00 %Vol 1.00 %Vol 5.00 %Vol 1.50 to 3.5 %Vol
Contact HA
2.5 %VOL CO
2
in Air
MPD-IV1
Methane 1226-0299 80 - 110 0 - 95 0 - 6 5.00 %Vol 1.00 to 5.00 %Vol 1.00 %Vol 5.00 %Vol 1.50 to 3.5 %Vol GFV352 2.5 %VOL CH
4
in Air
Methane 1226-0299 80 - 110 0 - 95 0 - 6 100 %LEL 1.00 to 5.00 %Vol 1.00 %Vol 5.00 %Vol 1.50 to 3.5 %Vol GFV352 2.5 %VOL CH
4
in Air
MPD-IF1 Flammables 1226-0300 80 - 110 0 - 95 0 - 6 100 %LEL 20 to 100 %LEL
3
10 %LEL 100 %LEL 30 to 70 %LEL GFV406 1 %VOL C
3
H
8
in Air
MPD-CB1 Flammables 1226A0359 80 - 120 see footnote 5 0 - 6 100 %LEL 20 to 100 %LEL
3
10 %LEL 100 %LEL 30 to 70 %LEL GFV352 50 %LEL CH
4
in Air
1. Agency approved hydrogen sensors are MPD-CB1 and 705 STD.
2. When ordering replacement MPD sensor cartridges, the replacement cartridge must be the same type as factory congured. Substituting a different cartridge
will void agency certication.
3. On XNX %LEL units carrying UL/CSA certications, the range is xed at 100%LEL and is not adjustable.
4. Humidity: 5% to 95% RH non-condensing
5. Humidity: 0 to 99% RH non-condensing
Loading ...
Loading ...
Loading ...