CYLINDER HEAD
EM-107
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
M
A
EM
Revision: 2004 November 2004 FX35/FX45
VALVE SEAT CONTACT
After confirming that the dimensions of valve guides and valves
are within specifications, perform this procedure.
Apply prussian blue (or white lead) onto contacting surface of
valve seat to check the condition of the valve contact on the sur-
face.
Check if the contact area band is continuous all around the cir-
cumference.
If not, grind to adjust valve fitting and check again. If the contact-
ing surface still has NG conditions even after the re-check,
replace valve seat.
VALVE SEAT REPLACEMENT
When valve seat is removed, replace with oversized (0.5 mm, 0.020 in) valve seat.
1. Bore out old seat until it collapses. Boring should not continue beyond the bottom face of the seat recess
in cylinder head. Set the machine depth stop to ensure this.
CAUTION:
Prevent to scratch cylinder head by excessive boring.
2. Ream cylinder head recess diameter for service valve seat.
Be sure to ream in circles concentric to the valve guide center.
This will enable valve to fit correctly.
3. Heat cylinder head to 110 to 130°C (230 to 266°F) by soaking in
heated oil.
4. Provide valve seats cooled well with dry ice. Force fit valve seat into cylinder head.
CAUTION:
Avoid directly touching cold valve seats.
Cylinder head contains heat. When working, wear protective equipment to avoid getting burned.
SBIA0322E
Oversize [0.5 mm (0.020 in)]
Intake: 38.500 - 38.516 mm (1.5157 - 1.5164 in)
Exhaust: 32.700 - 32.716 mm (1.2874 - 1.2880 in)
SEM795A