4 CHECK SWIRL CONTROL VALVE CONTROL VACUUM CHECK SWITCH INPUT SIGNAL CIRCUIT FOR
OPEN AND SHORT
1. Disconnect ECM harness connector.
2. Check harness continuity between ECM terminal 55 and swirl control valve control vacuum check switch terminal 1.
Refer to Wiring Diagram.
Continuity should exist.
3. Also check harness for short to ground and short to power.
OK or NG
OK © GO TO 5.
NG © Repair open circuit, short to ground or short to power in harness connectors.
5 CHECK SWIRL CONTROL VALVE CONTROL VACUUM CHECK SWITCH
1. Turn ignition switch “OFF”.
2. Disconnect vacuum hose connected to swirl control valve control vacuum check switch.
3. Attach vacuum pump to swirl control valve control vacuum check switch.
4. Turn ignition switch “ON”.
5. Check voltage between ECM terminal 55 and ground under the following conditions.
SEF709X
OK or NG
OK © GO TO 6.
NG © Replace swirl control valve control vacuum check switch.
DTC P1165 SWIRL CONTROL VALVE CONTROL VACUUM CHECK SWITCH
Diagnostic Procedure (Cont’d)