21 DETECT MALFUNCTIONING PART
Check the following.
I EVAP canister for damage
I EVAP hose between EVAP canister and water separator for clogging or poor connection
© Repair hose or replace EVAP canister.
22 CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR SHIELD CIRCUIT FOR OPEN AND SHORT
1. Reconnect harness connectors disconnected.
2. Disconnect harness connectors B2, M2.
3. Check harness continuity between harness connector M2 terminal 10 and engine ground.
Continuity should exist.
4. Also check harness for short to power.
OK or NG
OK © GO TO 24.
NG © GO TO 23.
23 DETECT MALFUNCTIONING PART
Check the following.
I Harness connectors B2, M2
I Harness connectors M81, F49
I Joint connector-17
I Harness for open or short between harness connector M2 and engine ground
© Repair open circuit or short to power in harness or connectors.
24 CHECK INTERMITTENT INCIDENT
Refer to “TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT”, EC-144.
© INSPECTION END
GI
MA
EM
LC
FE
AT
AX
SU
BR
ST
RS
BT
HA
SC
EL
IDX
DTC P0450 EVAPORATIVE EMISSION (EVAP) CONTROL SYSTEM PRESSURE
SENSOR
Diagnostic Procedure (Cont’d)
EC-401