Diagnostic Procedure
NHEC0530
PROCEDURE A
NHEC0530S01
1 INSPECTION START
Do you have CONSULT-II?
YesorNo
Yes © GO TO 2.
No © GO TO 3.
2 CHECK SWIRL CONTROL VALVE CONTROL SOLENOID VALVE CIRCUIT
With CONSULT-II
1. Turn ignition switch “ON”.
2. Select “SWIRL CONT SOL/V” in “ACTIVE TEST” mode with CONSULT-II.
3. Touch “ON” and “OFF” on CONSULT-II screen.
SEC012C
4. Make sure that clicking sound is heard from the swirl control valve control solenoid valve.
OK or NG
OK © GO TO 6.
NG © GO TO 3.
DTC P1130 SWIRL CONTROL VALVE CONTROL SOLENOID VALVE
Diagnostic Procedure