18 CHECK ABSOLUTE PRESSURE SENSOR
1. Remove absolute pressure sensor with its harness connector connected.
SEC004C
2. Remove hose from absolute pressure sensor.
3. Install a vacuum pump to absolute pressure sensor.
4. Turn ignition switch “ON” and check output voltage between ECM terminal 80 and engine ground under the following
conditions.
SEF300X
CAUTION:
I Always calibrate the vacuum pump gauge when using it.
I Do not apply below −93.3 kPa (–700 mmHg, –27.56 inHg) or over 101.3 kPa (760 mmHg, 29.92 inHg) of pressure.
OK or NG
OK © GO TO 19.
NG © Replace absolute pressure sensor.
19 CHECK FUEL TANK TEMPERATURE SENSOR
1. Remove fuel level sensor unit.
2. Check resistance between fuel level sensor unit and fuel pump terminals 4 and 5 by heating with hot water or heat gun
as shown in the figure.
SEF587X
OK or NG
OK © GO TO 20.
NG © Replace fuel level sensor unit.