8 CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR INPUT SIGNAL CIRCUIT FOR OPEN AND
SHORT
1. Disconnect ECM harness connector.
2. Check harness continuity between ECM terminal 84 and EVAP control system pressure sensor terminal 2.
Refer to Wiring Diagram.
Continuity should exist.
3. Also check harness for short to ground and short to power.
OK or NG
OK (With CONSULT-II) © GO TO 10.
OK (Without CONSULT-
II)
© GO TO 11.
NG © GO TO 9.
9 DETECT MALFUNCTIONING PART
Check the following.
I Harness connectors B2, M2
I Harness connectors M81, F49
I Harness for open or short between ECM and EVAP control system pressure sensor
© Repair open circuit or short to ground or short to power in harness or connectors.
10 CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
With CONSULT-II
1. Start engine.
2. Perform “PURG VOL CONT/V” in “ACTIVE TEST” mode with CONSULT-II. Check that engine speed varies according
to the valve opening.
SEF985Y
OK or NG
OK © GO TO 12.