Overview
Connection example for MCS mode
Regarding the power supply of a switching hub
The power consumption of the PoE of this control panel is 7 W.
Use a hub capable of supplying enough power for all
connected RCPs.
In MCS mode, be sure to set one of the multiple MSUs as the master. Not to turn off the power or disconnect the cable of
the master MSU during operation.
The maximum number of devices that can be directly connected to the network is 96 excluding the master MSU. This
maximum number does not include any RCP connected by CCA cable to a CCU connected to the network or any CCU
connected by CCA cable to a RCP connected to the network. A client MSU is counted as one unit.
A CNU and VCS cannot be connected to a system that will be used in MCS mode.
Camera heads
CCU
MSU-1000/1500
RCP-1500
PoE compatible switching hub
LAN straight cable
(category 5 or above)
RCP-1501
RCP-1530