User Manual - Page 578

For 2002 NISSAN MAXIMA.

Loading ...
Loading ...
Loading ...
Diagnostic Procedure
NFEC1095
1 CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE POWER SUPPLY CIRCUIT
1. Turn ignition switch “OFF”.
2. Disconnect EVAP canister purge volume control solenoid valve harness connector.
SEC929C
3. Turn ignition switch “ON”.
4. Check voltage between EVAP canister purge volume control solenoid valve terminal 2 and engine ground with CON-
SULT-II or tester.
SEC062D
Voltage: Battery voltage
OK or NG
OK © GO TO 3.
NG © GO TO 2.
2 DETECT MALFUNCTIONING PART
Check the following.
I Harness connectors E15, F18
I Harness connectors F58, F197
I Harness for open or short between EVAP canister purge volume control solenoid valve and ECM relay
© Repair harness or connectors.
3 CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE OUTPUT SIGNAL CIRCUIT
FOR OPEN AND SHORT
1. Turn ignition switch “OFF”.
2. Disconnect ECM harness connector.
3. Check harness continuity between ECM terminal 10 and EVAP canister purge volume control solenoid valve terminal 1.
Refer to Wiring Diagram.
Continuity should exist.
4. Also check harness for short to ground and short to power.
OK or NG
OK © GO TO 5.
NG © GO TO 4.
DTC P1444 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
Diagnostic Procedure
EC-578
Loading ...
Loading ...
Loading ...