Loading ...
Loading ...
Loading ...
6
QUICK REFERENCE GUIDE
Programming
Number
Page Description of Task
Factory
Setting
Programming
Procedure
57
36
Delete an Entry Code 57 # (entry code) #
58 37
Assign Utility Option Off 58 # (entry code) # (Option; 0=Off,
1=Daily, 2=Weekly, 3=Never) # (number
of uses 1-15)
59 37
Assign Special Use Entry Code 59 # (entry code) # enable/disable #
60 24
Assign Each External Access
Control Device a “Door Number”
Main keypad
assigned door1
Device 1=door 1
Device 2=door 2
Device 3=door 3
Device 4=door 4
60 # (device 1-4) # (door 1-4) #
61 24
Assign “Each” Door Number to
One or More Relays
D1=Relay 1
D2=Relay 2
D3=Relay 3
D4=Relay 4
61 # (door 1-4) # (relays to activate
0000-1111) # Order of relay is: relay
4-relay -3 -relay 2-relay 1 for an example
if you want relay 4 active you would enter
1000, if you want relay 1 active you
would enter 0001
63 46
Assign Door Use Time Zone Enabled 63 # (door 1-4) # (time zone, 0-63) #
64 48
Set Anti-Passback Entry/Exit for
Specific Devices
Disabled 64 # (device 0-4) # (0-3; 0=disable, 1=set
device to timed anti-passback, 2=set
device to true anti-passback-entrance,
3=set device for true anti-passback-exit)
#
65 23
Set Each “Relay Mode” to get
the Appropriate Response
All Relays =
“1-Strike”
65 # (relay 1-4) # (1=strike, 2=shunt,
4=alarm, 5=control) #
66 23
Set Each Relay’s “Activation
Time”
All Relays =
10 seconds
66 # (relay 1-4) # time (1-300 seconds)
67 61
Request to Exit Device (REX) R1=Door 1
R2=Door 2
R3=Door 3
R4=Door 4
67 # (REX number 1-4) # (select REX
option: 0=disabled, 1=use your door
settings or 2=use specific relay(s)
0000-1111) # Order of Relays are 4321
68 62
Door Sensing Devices DS1=Door 1
DS2=Door 2
DS3=Door 3
DS4=Door 4
68 # (sensor number 1-4) # (select
sensor option: 0=disabled, 1=use your
door settings or 2=use specific relay(s)
0000-1111) # Order of Relays are 4321
69 60
Postal Lock Switch Door 1 69 # (door 0-4; 0=no postal lock) #
70 60
Autocall Device 0000 70 # (relays to activate 0000-1111) #
Order of Relays are 4321 (Factory
Default: 0000)
71 43
Set the Default Card Type 30-bit 71 # (26 or 30) # (Factory Default: 30)
73 43
Set the Default Facility Code 0 73 # (0-255) #
74 43
Enable or Disable Ignore Facility
Code when a Card is Used
Enabled 74 # (0=disable; 1=ignore) #
75 36
Change Entry Code Door Access All Doors 75 # (entry code) # (door 0=any door,
1=door 1, 2=door 2, 3=door 3, 4=door 4)
#
78 40
Change Card Code Door Access All Doors 78 # (card code) # (facility code) #
(card type, 26 or 30) # (door 0=any door,
1=door 1, 2=door 2, 3=door 3, 4=door 4)
#
80 40
Add a Basic Card 80 (card PIN code) # (facility code) #
(card type, 26 or 30) #
Loading ...
Loading ...
Loading ...