The Anti-Passback feature deters someone from "passing back" his/her access code/card to unauthorized individuals
so they can gain entry into a restricted area. There are 2 types of anti-passback features:
True Anti-Passback requires residents to exit before entering again (and vice versa).
For example, if you have a door with Card Reader 1 (to enter) and Card Reader 2 (to exit), a resident entering
with Card Reader 1 will have to swipe his/her card in the Card Reader 2 to exit before swiping on Card Reader 1
again (and vice versa).
Timed Anti-Passback requires residents to wait a defined period of time before using the same access code
(card, entry code, etc.) again on the same entry device (reader, keypad, etc.)
For example, if you set the Timed Anti-Passback to 60 minutes, the system will not grant access for 60 minutes
to anyone who tries to reenter the same code into the same reader.
SETTING ANTI-PASSBACK
Enable or Disable Anti-Passback: 12
1
Press Then
2
Enable True Enable (1) or Disable (0). Then (#)
Enable or disable the anti-passback feature. You may only enable the door(s) for timed or true anti-passback.
Factory Setting: Disabled
1 2 3
Set Anti-Passback Entry/Exit for Specific Devices: 64
1
Press Then
2
Enter Entry Device (0-4). Then (#)
1 2 3
Set the anti-passback to function for specified entry devices (e.g., card readers, keypads, etc.). When setting
devices for "true" anti-passback, set one device for "entry" and the other for "exit". Only Wiegand devices may
use true anti-passback.
Factory Setting: Disabled
IMPORTANT: The Anti-Passback feature will not function unless you enable Program Number 12 (see above).
3
Enter Anti-Passback Option. Then (#)
Disabled=0, True Anti-Passback Entrance=2
Timed Anti-Passback=1, True Anti-Passback Exit=3
Set Anti-Passback Time: 13
1
Press Then
2
Enter Number of Minutes (1-60). Then (#)
With "timed" anti-passback, after a resident uses a card/code/remote control on a specific entry device, they
cannot use the device again until a specified amount of time elapses.
Factory Setting: 3 Minutes
3
Enable Timed Enable (1) or Disable (0). Then (#)
EXAMPLE:
Enables Timed Anti-Passback.
EXAMPLE:
Sets Device "1" for Timed Anti-Passback.