When a postal carrier triggers a postal lock switch, the assigned door number’s relay will activate. The postal entry
door should be near the postal lock switch. Once the postal input is detected then the relays for the door activate
for their programmed time. They do not stay active if postal input remains triggered. Factory Setting: Door 1
Postal Lock Switch:
69
1
Press Then
2
Enter Door Number to be Opened (0-4, 0=No Postal Lock). Then (#)
1 2
Factory Settings: Door 1 activates Relay 1, Door 2 activates Relay 2,
Door 3 activates Relay 3, Door 4 activates Relay 4
NOTE: A "Door Number" is an external
access control device where the
postal carrier can gain entry.
IMPORTANT: Whatever you assigned
Your” Door Settings applies to this
setting. See page 25.
Autocall Device: 70
To enter programming mode from the unit
Press *** and the 6-Digit Password (2 short beeps will be heard)
Exiting programming mode allows changes to take effect
1
Press Then
2
Enter Relays to be Activated (0000-1111). Then (#)
0=Deactivate, 1=Activate (1st digit=Relay 4, 2nd digit =Relay 3, etc.)
The Autocall device calls the resident and can activate specific relays (a light or a buzzer).
IMPORTANT: The Pound Key (#) must be used as Data Field Separator and to Save Data at the end of the
sequence. Time must be entered using a 24-hour format (8am=0800, 3pm=1500 etc.). Audio Feedback:
Programming input is valid. Audio Feedback: Input is not valid. If you make an error during an entry, press the
asterisk key (*) to begin again.
21
Relay 4 Relay 3 Relay 2 Relay 1
Deact Deact Deact
Activate
EXAMPLE:
Assigns Postal Lock Switch to "Door 2".
EXAMPLE:
When a loop detector type device is triggered, only Relay "3" will activate.
POSTAL LOCK/AUTOCALL/EXIT/DOOR
SENSOR DEVICES