96 Part Number STH14 9/10
8. A flavor tab for the 4th flavor will have to be added
to the touch pad. To do this, obtain one (1) P/N
5030780 20 flavor decal pad. Remove the P/N
5031579 decal overlay and add the 4th flavor tab
as well as replace any flavor tabs which came off
when removing the decal overlay. Note position of
4th flavor on the touch pad in the picture and
placed tab where indicated. Obtain a new P/N
5031579 decal overlay and place over the tabs.
If the customer decides to go back to 3 flavors, it will
not be necessary to change the board back to 3
flavors. However, it can be done by following steps 1
through 6 above. The number “3” will appear on the
display. Then disconnect the number “4” syrup from
the system, remove the 5031579 decal overlay,
remove the flavor tab “4” and replace the 5031579
decal overlay. It would be a good idea to have an
additional P/N 5030780 in case flavor tabs are
damaged in the process.
STEADY OR FLASHING TOUCH PAD LED
The blue LED on the touch pad can be set to one of
two display modes:
1. Steady illumination. This is the default mode and
the LED will remain on steady until dispense is
activated. The light will flash only when product is
being dispensed. In this mode, the control board
display will read “Off”.
2. Flash mode. The LED will turn on for 1/2 second
and off for 1/2 second.
Enter the Flash mode by pressing the program button
until a flashing “- - - -” is displayed. Pressing flavor
button 1 (far left button) will switch from “Off” (default)
to “On”. The LED will now flash. To change back to the
default simply press flavor button 1 again and the
display should read “Off”. Press program button to exit
to the next program function.