Part Number STH14 9/10 91
Carbonator Switch
(Switch in OFF position for
External Carb. and Juice
units, which turns off green
carbonator LED.)
Switch supplies power to the
carbonator float switch and green
Carbonator LED only.
Green Carbonator LED
(Turned off on External
Carb. and Juice Units)
The green carbonator LED
illuminates when carbonator
switch is in the ON position (only
applies to Internal Carb. units).
The green carbonator LED will
flash rapidly when the carbonator
motor is running.
Carbonator Fill Timing
Jumper
(Not used on External Carb.
or Juice Units)
Carbonator tank fill timing
provides pump failure protection
in the event of water loss to
carbonator pump (only applies to
Internal Carb. units).
A jumper clip within the control
box sets the three optional time
settings. Units are shipped with
the jumper in (7) minute position
(only applies to Internal Carb.
units).
NOTE: Time tolerance is ±20%.
NOTE: See default mode functions
Green Compressor LED Illuminates when the compressor
switch is in the ON position.
Flashes once per second when
the compressor and condenser
fan are energized.
Element Function
J1 J1 J1
3 Minute 7 Minute Unlimited