Part Number STH14 9/10 89
Operation
Blade Tower Brixing
NOTE: Each tower consists of two valves combined as
one with a mixer block, mixer tube and mixer. One
Pre-ME valve (CMBEGKER) and one Flomatic 424
Flow Control Base
Set water flow rate first:
1. Turn off syrup shut-off at post-mix (424) valve
block.
2. Use stop watch to time the dispense of soda
water only.
3. Dispense for 5 seconds.
4. Record volume in a volume cup or ratio cup.
5. Adjust the water flow rate as needed until
10 ounces (283.5 g) of water is measured in a
5 second (2 oz [56.7 g]/sec) dispense.
Set the syrup flow rate:
1. Adjust the ratio (brix) of water to syrup (4.75:1) or
12.3 to 12.7 brix)
2. Turn on syrup shut-off and turn off the water shut-
off.
3. Use a stop watch to time the dispense of syrup
only.
4. Dispense for 5 seconds.
5. Record volume in a volume cup or ratio cup.
6. Adjust syrup flow rate as needed until 2 ounces
(56.7 g) of syrup is measured in a 5 second
dispense.
7. Use a refractometer if possible to get final brix
ratio of 12.3 to 12.7. You will have to rely on
volume adjustment above for diet products.