User Manual - Page 124

For 2705138.

Loading ...
Loading ...
Loading ...
124 Part Number STH14 9/10
Agitation Timer
The timer is non-adjustable and is set to agitate the ice
for 3 seconds every 3.5 hours. Activating the
dispenser will reset the timer. After 3.5 hours of
non-use, the timer will energize the dispenser motor.
The LED tells the technician in which mode the timer is
operating. Rather than a jumper pin, this timer has a
female spade connector that must be connected to
terminal number 6.
When this jumper is in place, the LED will blink at
one-second intervals, this is the run mode.
When the jumper is open, the LED will flash every
0.4 second. This is the test mode and the timer will
cycle every 55 seconds in test mode. If the timer is left
in test mode, it will automatically reset to run mode.
Agitation Timer
1
RED
NO
2
3
6
4
5
COM NC
STH14.book Page 124 Thursday, September 23, 2010 3:35 PM