134 Part Number STH14 9/10
FLAVOR MAGIC & FRP-250 FLAVOR SHOTS
Problem Possible Cause Corrective Action
Flavor shot syrup
does not dispense
when flavor button
is pressed
Syrup supply
depleted
Replace syrup.
CO
2
supply depleted Replace CO
2
.
B-I-B disconnect
loose or packed with
dried syrup residue
Tighten and/ or clean B-I-B
disconnect.
CO
2
Regulator set to
low
Check CO
2
regulator for proper
setting — 30 PSI (1 Bar) or
according to line run.
Kinked CO
2
or syrup
line
Check lines for kinks.
B-I-B pump
inoperative
Check pumps, replace if
needed.
Valve solenoid
inoperative
Check wiring to valve, replace
solenoid.
Vinyl tubing off at
nozzle or at solenoid
Reconnect tubing.
Vinyl tubing plugged
with syrup at nozzle
or at solenoid
Clean tubing and nozzle.
Board not in
dispense mode
Place control board into
dispense mode “0”.
No power to
control board
Disconnected or
loose wires
Check connector to transformer
and corresponding control
board.
No power to
transformer
Check power supply at
transformer — 24 VAC.
Flavor syrup does
not shut off
Check for stuck
solenoid
Replace solenoid if it continues
to stick.
STH14.book Page 134 Thursday, September 23, 2010 3:35 PM