140 Part Number STH14 9/10
Minimum Circuit Amperage Chart
NOTE: For FlexTower applications — A dedicated
120 VAC, 15 ampere circuit is required to provide
power to the power supply’s transformer with an
output of 24 VAC for the electric valves, 120 VAC,
8 ampere circuit, and to power a cold water
recirculation pump. The power supply has a 120 VAC
outlet to provide power for the cold water recirculation
pump.
Important
Due to continuous improvements, this information
is for reference only. Please refer to the
dispenser serial number tag to verify electrical
data. Serial tag information overrides information
listed on this page.
Dispenser Voltage/Cycle
Minimum
Circuit Amps
CEV-30, CEV-40 120/60 8.2
208-230/60,
220-240/50Hz
DI-1522, CT-6 120/60 2.4
220/50
DI/DIL2323, CT-8 120/60 3.2
220/50
Flavor Magic 24VAC, powered
by existing valve
transformer on
dispenser
0.5
FlexTower 120/60 2.5
FRP-250 120/60 3.0
MDH-302, MDH-402 120/60 3.5
MDH-302SCI,
MDH-402SCI
120/60 5.4
S-150, S-200, S-250,
SV-150, SV-175,
SV-200, SV-250,
SV-150i, SV-175i,
SV-200i, SV-250i,
SV-250QD, NGF-250,
NGF-250QD
115/60 2.8
220/50, 220/60,
240/50, 240/60
1.5
220-240/50 5
(with carb
deck)
STH14.book Page 140 Thursday, September 23, 2010 3:35 PM