Part Number STH14 9/10 121
1. To set the ice portion sizes, press the program
switch 1 time in 3 seconds. The display will read
“0001”.
2. Press the ice portion size that is to be adjusted.
Once the portion size that is to be adjusted is
pressed, the display will show the present pulse
setting for that size.
3. To increase the portion size, press the largest
size button. To decrease the portion size, press
the smallest size button.
NOTE: The pulse count will increase, or decrease, by
1 with each press of the smallest or largest size
buttons.
4. Press the program button 1 time to exit program
mode and save settings.
5. Repeat steps 1 through 4 for each cup size as
necessary.
NOTE: For Data Display Mode, and Test Mode
instructions please refer to the Quickdraw Portion
Control Program flow chart in this manual.
Free movement of the metering wheel is essential for
consistent ice portion sizes.
One Adjustment Screw on Each Side of
QD Assembly