Chapter 10 Notes — Warning system
Warning system
When an error is detected right after the camera is turned on or during the operation, the occurrence of the error is notied in the camera image screen
of the LCD monitor or by the tally lamp. Deal with the error by following the indications.
Cases indicated by error messages
System error
Screen display
Description Behavior and cause
Camera image screen
[SYSTEM ERROR] An error in the standard signal or communication error has
occurred.
All the tally lamps and the card access lamps (orange) will
ash four times a second, and an alarm is sounded.
f Set the power to < h > (standby).
Warning
Screen display
Description Behavior and cause
Camera image screen
[LOW BATTERY] Remaining battery level is insufcient. All the tally lamps and the card access lamps (orange) will
ash four times a second, and an alarm is sounded.
The power status display becomes
, and it will ash
once every second in red.
f The power is turned off in approximately ve seconds.
f Replace with a fully charged battery, or connect the AC
adaptor.
[HIGH TEMPERATURE] Displayed when the internal temperature of the camera has
risen above assumed.
All the tally lamps and the card access lamps (orange) will
ash four times a second, and an alarm is sounded.
f The power is turned off in approximately ve seconds.
f Turn on the power again and check recording and
playback operations. If the problem persists, consult the
dealer.
[REC WARNING] An error of the recording data has occurred during
recording, and the recording has stopped.
All the tally lamps and the card access lamps (orange) will
ash four times a second, and an alarm is sounded.
f Recording is stopped.
It has tried to record exceeding the maximum number of
clips during recording.
All the tally lamps and the card access lamps (orange) will
ash four times a second, and an alarm is sounded.
f Recording is stopped.
f [REC WARNING] [<OVER MAX NUM. OF CLIPS>] is
displayed in the warning display eld of the STATUS
screen for the mode check.
f Replace the memory card or delete unnecessary clips.
[CARD ERROR <SLOT 1>]/[CARD
ERROR <SLOT 2>]
A data error caused by the memory card has occurred
during recording or playback.
f When it was recording
All the tally lamps and the card access lamps (orange)
will ash four times a second, and an alarm is sounded.
Recording is stopped.
The memory card where the error has occurred is write
protected after recording stops. Replace the memory
card in the card slot where the error has occurred.
f When it was playing back
Playback is stopped.
[END]
(Memory card status display)
The remaining recording capacity of the memory card has
exhausted during recording.
All the tally lamps and the card access lamps (orange) will
ash four times a second, and an alarm is sounded.
f Recording is stopped.
f Replace the memory card or delete unnecessary clips.
(Once every second, ash in red)
Battery is almost consumed. All the tally lamps will ash once every second.
f The current operation will continue.
f Replace with a fully charged battery, or connect the AC
adaptor.
Remaining recording capacity display
of the memory card
(Flashes once every second during
recording)
The remaining recording capacity of the memory card is
getting low.
f Recording will continue.
f Replace the memory card as necessary.