RIGOL Chapter 13 Pass/Fail Test
13-4 DS8000-R User Guide
To Set the Output Form of the Test Results
Click Option to enter the "Option" menu. You can set what the oscilloscope will
execute when test results are detected according to your needs.
âš« Set the output event and Aux output
➢ Click Output Event to select "Fail" or "Pass".
➢ Click Aux Output continuously to enable or disable the Aux output. If
enabled, open the function navigation menu, and then click Utility →
System, and then the AUX Out is automatically set to "PassFail". When a
successful or failed event is detected, a pulse will be output from the
rear-panel [TRIG OUT] connector. If the Aux output is disabled, click
Utility → System, and then the AUX Out is automatically set to "TrigOut".
The output of the rear-panel [TRIG OUT] connector is irrelevant with the
pass/fail test.
âš« Set the output polarity and output pulse width
Click Polarity continuously to select "Positive" or "Negative". Then click Pulse,
use the pop-up numeric keypad or scroll with the mouse to set the pulse width.
Its range is from 100 ns to 10 ms. By default, it is 1 μs.
âš« Set the error action
Click Err Action to set the operation that the oscilloscope will execute once a
failed test is detected.
➢ Stop: indicates stopping test when a failed test event is found.
➢ Beeper: indicates that the beeper sounds an alarm when a failed test
event is found (irrelevant with the on/off status of the beeper).
➢ Screenshot: performs the screenshot operation when a failed test event is
found. If an external storage device is detected, the screenshot will be
saved to the external storage device directly. Otherwise, it will be saved to
the local disk.
Note: If "Screenshot" is selected under Err Action, the test will be
stopped forcibly. After capturing the screenshot, the test will continue.
To Enable or Disable the Display of the Statistics
of the Test Results
Click Information continuously to enable or disable the display of the statistics of
the test results. You can also click on the icon
at the right-upper corner of the
statistics window to close it.
The test results statistics include the number of failed frames, the number of
successful frames, and total number of frames, as shown in the figure below.
Loading ...
Loading ...
Loading ...