Rigol DS7024 Oscilloscope

User Manual - Page 311

For DS7024.

PDF File Manual, 374 pages, Read Online | Download pdf file

DS7024 photo
Loading ...
Loading ...
Loading ...
Chapter 17 Function/Arbitrary Waveform Generator (MSO7000 Option) RIGOL
MSO7000/DS7000 User Guide 17-19
Type continuously or enable the touch screen to select it. The available burst
types include N Cycle and Infinite.
âš« N Cycle: outputs the burst waveforms with a specified number of cycles
once receiving the trigger signal.
âš« Infinite: sets the number of cycles to Infinite. It outputs continuous
waveforms once receiving the trigger signal.
2. Set the Number of Cycles
When the burst type is set to "N Cycle", you need to set the number of cycles.
Press Cycles, then rotate the multifunction knob or use the pop-up numeric
keypad to set the number of cycles. For the Infinite burst type, the Cycles menu
is disabled and grayed out.
3. Set the Burst Delay
Burst delay indicates the time from when receiving the trigger signal to starting
to output N Cycle of bursts or Infinite burst.
Press Delay, then rotate the multifunction knob or use the pop-up numeric
keypad to set the desired delay time. The range of the delay time related to the
burst cycles.
4. Burst Setting
Press Settings to enter the burst setting menu.
âš« Set the trigger source
The trigger sources of the burst can be Internal or Manual. When the
Function/Arbitrary Waveform Generator receives a trigger signal, a burst
output is generated, and then it waits for another trigger signal.
Press Trig Source and rotate the multifunction knob to select the
desired trigger source, and then press down the knob to select it. You can
also press Trig Source continuously or enable the touch screen to select it.
The available trigger sources include Internal and Manual. For the Infinite
burst type, the Trig Source menu is disabled and grayed out.
➢ Internal: the Function/Arbitrary Waveform Generator outputs
continuous N cycle bursts.
➢ Manual: when you press Manual Trig for one time, one burst output is
immediately launched for the corresponding channel. For the Infinite
burst type, the Cycles menu is disabled and grayed out.
âš« Set the burst period
It is defined as the time from the beginning of one burst to that of another
burst.
Press Burst Period, then rotate the multifunction knob or use the
pop-up numeric keypad to set the desired burst period. Its available range
is from 2 ms to 500 s. By default, it is 10 ms.
Loading ...
Loading ...
Loading ...