4. Telnet/SSH Console
4.2.4.2 Time Zone
This menu allows the user to select a time zone.
-------- Time zone ---------------------------------------------------------
Timezone Offset : Etc/UTC
1- Africa
2- America
3- Antarctica
4- Arctic
5- Asia
6- Atlantic
7- Australia
8- Europe
9- Indian
10- Pacific
X- Date/Time
M- Return to Main Menu
<ENTER> Refresh Menu
Menu Data
Time Zone Offset
The time zone offset from UTC. All times are entered as UTC and will be adjusted by the selected offset. Time zone offsets west of UTC are entered
as positive numbers, and time zone offsets east of UTC are entered as negative numbers.
-------- NTP Settings ---------------------------------------------------------
Primary Address : 0.pool.ntp.org
Secondary Address : 1.pool.ntp.org
1- Primary Address
2- Secondary Address
A- Apply Changes
X- Date/Time
M- Return to Main Menu
<ENTER> Refresh Menu
Menu Data
4.2.4.3 NTP Settings
This menu allows the user to control the various aspects of using NTP for setting the time and date.
Primary Address
This is the address for the primary NTP server. The default is 0.pool.ntp.org.
Secondary Address
This is the address of the secondary NTP server. The default is 1.pool.ntp.org.