25
3. The Web Interface
3.4.7 Configuration/Log Settings
The Log Settings page is used to configure the log rotation options for the supported log types: Accounting, Data and Events (Figure 3-37). A
maximum of 1024 lines will be stored in any of the logs before the log automatically rotates. The size of the log can be adjusted; the minimum is
64 lines and the maximum is 1024 lines. The log format can be chosen; options are xml and csv. Use the [+] button to assign an existing HTTP
or Email contact to receive the rotated logs (Figure 3-38). Click the [Save] button to save the settings at any time. In addition to log rotation
settings, Syslog and Application log settings can be configured. The only setting for the Application log is the minimum severity level system
message that should be logged (Figure 3-39). All higher-level messages will be logged automatically.
Figure 3-37: Log Settings Page
Figure 3-38: Assigning a Contact to Receive Logs