Loading ...
Loading ...
Loading ...
74
SIGNATURE RAILING
IMPORTANT NOTES:
» EACH POST MUST BE ATTACHED AS SHOWN TO ENSURE A CODE-
COMPLIANT AND SAFE INSTALLATION.
» SIGNATURE POSTS CANNOT BE USED WITH SIGNATURE TRADITIONAL
OR SIGNATURE COCKTAIL DESIGNS, ONLY Pressure-treated POST/POST
SLEEVES CAN BE USED. REFER TO DETAILED INSTRUCTIONS FOR MORE
INFORMATION.
» ALWAYS refer to your local building code official prior to installing
any railing system to ensure all code and safety requirements are met.
Trex® cannot be held responsible for improper or non-recommended
installations.
» When installing Signature posts on ACQ, CCA or concrete surfaces, use
an appropriate isolation barrier between post and surface (contact local
building code official if needed).
» For installing Signature Post and/or Signature Crossover Posts, see below.
» For pressure-treated posts, post sleeves, and skirts, see detailed
instructions provided with Signature Railing Kits.
» All Signature stair installations require the use of a 53" (1346 mm) stair
post, measured and cut to appropriate length if necessary.
» If crossover stair post is required, use stair post (again cut to
appropriate length if necessary) and use swivel crossover bracket.
» If installing on concrete, make sure all surfaces are level.
TOOLS AND MATERIALS NEEDED
»
Drill and/or screw gun (hammer drill for concrete)
»
1/2" (13 mm) drill bit for wood, 3/8" (10 mm) drill bit for concrete
»
Blocking – 2" x 8" (51 mm x 203 mm) pressure-treated Southern
Yellow Pine or equivalent
»
Qty: 36 (per post) – 3" pressure-treated compatible wood screws
CODE APPROVED POST APPLICATIONS
POST SIZE
< 30" height decking Acceptable (Code Approval not Applicable)
IRC Compliant Yes
IBC Compliant No
Installing Signature Posts and/or Signature
Crossover Posts on Pressure-treated Wood
Framing
(Corner Post Installation)
1. Install 2" x 8" (51 mm x 203 mm) cross bracing
frame in between joists at 7-1/4" (184 mm).
Attach
a total of twelve 3
"
(76 mm) pressure-treated
compatible screws (not provided).
2. Install two 2" x 8" (51 mm x 203 mm) boards as
blocking under post location. Securely attach
blocking using a total of twenty-four
3
"
(76 mm)
pressure-treated compatible screws (not provided).
NOTE: TO ENSURE THE BLOCKING IS FULLY SECURE,
USE THE AMOUNT OF SCREWS INDICATED ABOVE.
TIP: Use two additional screws to "sandwich" blocking
boards together for easier attachment to framing.
Line Post Installation
3. Install two 2
"
x 8
"
(51 mm x 203 mm) cross bracing
frames in between joists at 7-1/4
"
(184 mm). Attach
a total of twelve 3
"
(76 mm) pressure-treated
compatible screws (not provided).
4. Install two 2
"
x 8
"
(51 mm x 203 mm) boards as
blocking under post location. Securely attach
blocking using a total of twenty-four 3
"
(76 mm)
pressure- treated compatible screws
(not provided).
7-1/4
"
(18.4 cm)
7-1/4"
(18.4 cm)
2" x 8" Pressure-treated
Cross bracing frame
1
2
Blocking
boards
7-1/4"
(18.4 cm)
7-1/4
"
(18.4 cm)
3
Cross bracing
frame
Cross bracing
frame
4
Blocking
boards
2.5" (64 mm)
2.5" (64 mm)
2.5 x 2.5 (64 mm x 64 mm) Post (IRC)
INSTALLING SIGNATURE POSTS AND/OR SIGNATURE CROSSOVER
POSTS ON WOOD OR CONCRETE
Loading ...
Loading ...
Loading ...