FLASH MEASURE OF SEPARATE FLASH UNIT
You can measure the effect of an attached ash unit (with PC
connected ash units and SCA3902 compatible ash units
set to M mode), where the camera acts as a ash meter. The
aperture setting can be adjusted and more trial exposures made
until the information on the grip display is satisfactory.
To use ash measure:
1 Assign a button as FLASH button.
2 Press the Assigned button on to access the ash option
screen.
3 Turn the Rear control wheel until Flash measure appears.
4 Make preliminary required aperture setting by turning the
front control wheel.
5 Press the AE-L button. The camera will close the aperture,
raise the mirror and re the ash. Light reected from the
ash lit subject will be reected off a white spot on the
auxiliary shutter to the meter sensor.
6 Deviations from a normal exposure are displayed as
differences in EV on the grip display and the viewnder
display. If ‘High’ or ‘Low’ appears, change the aperture
accordingly and make a new test reading.
Change the aperture until Diff EV: 0 appears, or the desired
amount of deviation from the normal exposure.
Diff EV
Low = more than 2 EV below.
Diff EV
High = more than 2 EV above.
Note!
The ‘Low Flash’ warning can be disabled in Main Menu on the
Sensor Unit Display Settings.