LOOKING AFTER YOUR HAND DRYER
WARNING
This product is not to be used in sinks where a plug is fitted. Before engaging the water
flow ensure that the plughole is clear of any obstructions and that water can drain freely.
HOW TO USE
Place your hands beneath the Dyson hand dryer and it will automatically, creating sheets of air
to scrape water from your hands.
For best dry time results:
Keep your hands flat and parallel to the appliance surface, approximately 5 mm from the
blade, drawing your hands through the airflow from your wrists to finger tips.
Move your hands slowly through the airflow keeping a consistent speed, approx. 2.5 seconds
per side, alternating between front and back each time.
Keep you hands flat, close the gaps between your fingers and keep your thumbs in to ensure
that the whole of your hand is drawn through the airflow.
TROUBLESHOOTING GUIDE
WARNING: RISK OF ELECTRIC SHOCK!
Problem Action
The hand dryer fails to start. Check that the fuse/circuit breaker is working
and that the power is connected. Must be
performed by a qualified electrician.
Ensure that the cleaning cap is removed and
that the sensors are clean and unobstructed.
If a safe method of switching is available,
turn the unit on and off. If a safe method is
not available, a qualified electrician must
perform this task.
The hand dryer is turning on and
off erratically.
Ensure that the sensors are clean and free
from obstructions.
Check that the sensor cable from the tap is
securely connected. Must be performed by a
qualified electrician.
The hand dryer sometimes cuts out when
in use but resumes operation after a period
of time.
Check that the air inlet is clean and free
of dust.
Remove any dust from the air inlet.
Ensure that the air inlet is free from
obstructions and has sufficient clearance
(see installation instructions).
The dry time of the hand dryer has increased. Inspect the inlet grille for dust and remove.
Inspect the filter and change if required.
Ensure that the hose is securely attached to
the base of the tap and no leaks are present.
Must be performed by a qualified electrician.
NOTE: Ensure water feed is completely flushed of debris, copper filings etc. prior to
connecting to the product. Failure to do so will damage the solenoid valve.
The instructions in this manual and the installation guide must be followed completely,
as failure to do so may result in incorrect operation, damage to property and/or
personal injury. It is recommended that an isolation valve is fitted with this product
during installation. Dyson will not be held liable for any damage to property or
personal injury, or any loss of business or revenue, if you, your staff, your installer
or service engineers have not followed the instructions given in this manual and the
installation guide.