Current
Shunt
Range ..............................................................0.1 A, 1 A, 10 A
Crest Factor ....................................................CF 2
Overload Capacity ...........................................10 % overload
Input Impedance .............................................0.025 Ω (Typical)
Temperature Coefficient .................................0.05 x (Spec)/K
Bandwidth .......................................................10 A range: 500 kHz
1A range: 200 kHz
0.1A range: 100 kHz
BNC
Range .............................................................0.1 V, 1 V, 10 V
Crest Factor ....................................................CF 2
Overload Capacity ...........................................10 % overload
Input Impedance .............................................100 kΩ / 100 pF
Temperature Coefficient .................................0.05 x (Spec)/K
Bandwidth .......................................................10 V range: 500 kHz
1 V range: 200 kHz
0.1 V range: 100 kHz
Accuracy
Accuracy (% reading + % range)
Motor (NORMA 6003+
NORMA 6004+)
Voltage Range....................................................±10 V dc, 10 % overload
Voltage Channels ..............................................2
Input Impedance.................................................1.1 MΩ (Typical)
Temperature Coefficient ....................................0.05 x (Spec)/K
Accuracy @ DC .................................................0.1 % reading + 0.1 % range
Pulse Channels ..................................................3
Pulse logic high threshold ..................................2 V (Typical)
Pulse logic low threshold ...................................0.8 V (Typical)
Maximum pulse frequency .................................100 kHz
Range DC
AC
10 Hz to 1 kHz 10 kHz
Shunt
10 A 0.1 + 0.2 0.1 + 0.1 5 + 1
1 A 0.1 + 0.5 0.1 + 0.2 5 + 1
0.1 A 0.1+2 0.1 + 1 5 + 1
BNC
10 V 0.1 + 0.1 0.1 + 0.1 5 + 1
1 V 0.1 + 0.2 0.1 + 0.1 5 + 1
0.1 V 0.1 + 1 0.1 + 0.5 5 + 1