6-9
6-9
Electrical Servicing
(1) FAN MOTOR RELAY
Fan motor relay inspection
Remove the fan motor relay.
Connect an ohmmeter to the fan motor relay connector
terminals.
Connection: Red – Blue
Connect a 12 V battery to the following fan motor relay
terminals.
Connection: Red – Black/Blue
There should be continuity only when the 12 V battery is
connected.
If there is no continuity when the 12 V battery is
connected, replace the fan motor relay.
(1) 2P (NATURAL) CONNECTOR
Cooling fan system inspection
Fan motor inspection
Remove the fuel tank.
Disconnect the fan motor 2P (Natural) connector.
Directly connect a 12 V battery to the fan motor 2P
(Natural) connector terminals of the fan motor side.
The fan motor is correct if the fan operates when a 12 V
battery is connected.
If the fan motor does not operate, replace the fan motor
assembly.
1
(1) CONNECTORS
Engine stop switch inspection
Disconnect the engine stop switch connectors.
Check the engine stop switch for continuity.
There should be continuity.
There should be no continuity when the engine stop
button is pushed.
Replace the switch if it is out of specification.
1
1