RIGOL Chapter 9 Histogram Analysis
9-4 MSO7000/DS7000 User's Guide
Sum: indicates the sum of all bins (buckets) in the histogram.
Peak: indicates the maximum number of hits in any single bin.
Max: indicates the value that corresponds to the maximum bin that has any hits.
Min: indicates the value that corresponds to the minimum bin that has any hits.
PKpK: indicates the Delta between the max. value and the min. value.
Mean: indicates the average value of the histogram.
Median: indicates the median value of the histogram.
Mode: indicates the mode value of the histogram.
Bin width: indicates the width of each bin (bucket) in the histogram.
Sigma: indicates the standard deviation of the histogram.
To Reset
Press Reset to reset the statistical data and restart to make statistics.