Hitachi ZAXIS 260F-FE-6N

User Manual - Page 340

For ZAXIS 260F-FE-6N.

PDF File Manual, 383 pages, Download pdf file

Loading ...
Loading ...
Loading ...
Miscellaneous—Storage
KR46761,00013B6 -19-02NOV16-1/1
Prepare Machine for Storage
IMPORTANT: Avoid machine damage. Do not use
biodiesel during machine storage. When
using biodiesel blends, switch to petroleum
diesel for long-term storage.
1. Before storage, operate engine on at least one
complete tank of petroleum diesel fuel to purge the
fuel system. Ensure that the fuel tank is full during
storage to prevent water buildup due to condensation.
NOTE: For blends up to and including B5, it is
recommended that biodiesel be used within 3
months of its manufacture. The poor oxidation
stability characteristic of biodiesel can result in
long-term storage problems. Hitachi does not
recommend using biodiesel in engines powering
standby applications or vehicles operating on a
seasonal basis. Consult an authorized Hitachi
dealer or fuel supplier for additives to improve fuel
storage and performance of biodiesel fuels. These
additives must be added to the biodiesel close to
its time of production for them to be effective.
2. Repair worn or damaged parts. If necessary, install
new parts to avoid needless delays later.
3. Replace air cleaner elements.
4. Drain water separator.
IMPORTANT: High-pressure washing greater than
1379 kPa (13.8 bar) (200 psi) can damage freshly
painted nishes. Paint should be allowed to
air dry for a minimum of 30 days after receipt
of machine before cleaning parts or machines
with high pressure. Use low-pressure wash
operations until 30 days have elapsed.
5. Wash the machine. Use low-pressure wash operations
(less than 1379 kPa [13.8 bar] [200 psi]) until 30 days
after receipt of machine have elapsed. Paint areas to
prevent rust. Replace decals where needed.
6. Apply oil to track chains. Run machine back and forth
several times. Park machine on a hard surface to
prevent tracks from freezing to ground.
T5813AM —UN—09FEB89
Prepare Machine for Storage
IMPORTANT: LPS Rust Inhibitor can destroy
painted nish. DO NOT spray LPS 3 Rust
Inhibitor on painted areas.
7. Retract all hydraulic cylinders if possible. If not, coat
exposed cylinder rods with LPS 3 Rust Inhibitor.
8. Lubricate all grease points.
NOTE: If the batteries are kept disconnected for more
than 1 month or when the batteries are reconnected,
resetting of the controllers may be required.
Contact an authorized Hitachi dealer.
9. Turn battery disconnect switch to the OFF position.
See Battery Disconnect Switch. (Section 2-3.)
10. Remove the batteries and store in a dry, protected
place after charging fully. If not removed, disconnect
the negative battery cable from the (-) terminal.
11. Add a fuel stabilizer additive and top off fuel tank with
fuel to prevent condensation.
12. Store machine in a dry, protected place. If stored
outside, cover with a waterproof material.
13. Place a DO NOT OPERATE tag on the right pilot
control lever.
14. Remove keys and lock all covers and doors.
LPS 3 Rust Inhibitor is a trademark of Illinois Tool Works
4-4-1
112321
PN=338
Loading ...
Loading ...
Loading ...