Maintenance—Every 1000 Hours
KR46761,0001426 -19-23NOV16-1/1
KR46761,0000BB7 -19-17APR17-1/1
Replace Fuel Tank Breather
1. Remove cap screws (1) and access cover (2).
2. Remove fuel tank breather (3) and discard.
3. Install new fuel tank breather.
4. Install cap screws and access cover.
1— Cap Screw (2 used)
2— Access Cover
3— Fuel Tank Breather
TX1227919 —UN—08NOV16
Access Cover
TX1227920 —UN—08NOV16
Fuel Tank Breather
Check Coolant Condition
CAUTION: Prevent possible injury from hot,
spraying uids. Shut off engine. Remove ller
cap only when cool enough to touch with bare
hands. Slowly loosen cap to relieve pressure
before removing completely.
NOTE: Coolant should be checked every 1000 hours or
1 year, or when replacing 1/3 or more of coolant
using SERVICEGARD™ tool program.
1. Open engine cover to access surge tank.
2. Test engine coolant. See Testing Coolant Freeze
Point. (Section 3-1.)
3. Install surge tank cap.
TS281 —UN—15APR13
Pressurized Fluids
4. Close engine cover.
SERVICEGARD is a trademark of Deere & Company