Miscellaneous—Machine
OUT4001,0000238 -19-09MAR17-1/1
KR46761,00013DF -19-17OCT16-1/1
Using Booster Batteries—24-Volt System
Before boost starting, machine must be properly shut
down to prevent unexpected machine movement when
engine starts.
CAUTION: An explosive gas is produced while
batteries are in use or being charged. Keep ames
or sparks away from the battery area. Make sure
the batteries are charged in a well-ventilated area.
IMPORTANT: The machine electrical system is a
24-volt negative (-) ground. Connect two 12-volt
booster batteries together as shown for 24 volts.
1. Connect one end of the positive (+) cable to the
positive (+) terminal of the machine batteries (A) and
the other end to the positive (+) terminal of the booster
batteries (B).
2. Connect one end of the negative (-) cable to the
negative (-) terminal of the booster batteries. Connect
the other end of the negative (-) cable to the machine
frame as far away from the machine batteries as
possible.
3. Start engine.
T7233JN —UN—21MAY90
Booster Batteries, 2-Battery Application
A—Machine Battery (2 used) B—Booster Battery (2 used)
4. Immediately after starting engine, disconnect the end
of the negative (-) cable from the machine frame. Then
disconnect the other end of the negative (-) cable from
the negative (-) terminal of the booster batteries.
5. Disconnect positive (+) cable from booster batteries
and machine batteries.
Replacing Batteries
CAUTION: Avoid personal injury from battery acid.
Always wear protective equipment. Sulfuric acid
in battery electrolyte is poisonous. Sulfuric acid is
strong enough to burn skin, eat holes in clothing,
and cause blindness if splashed into eyes.
NOTE: Reserve capacity is the time in minutes it
takes a fully charged battery at 26.6°C (80°F)
to drop below 10 volts.
Turn battery disconnect switch to the OFF position. See
Battery Disconnect Switch. (Section 2-3.)
Open left rear service door to access batteries (1).
This machine has two 12-volt batteries with negative (-)
ground connected in series to provide 24 volts.
Only use batteries which meet the following specications:
Specication
Battery—Cold Cranking
Amps (CCA) at -18°C
(0°F) per Battery.......................................................................1000 CCA
Battery—Minutes
Reserve Capacity at 25
Amps per Battery......................................................................... 440 min
TX1226253 —UN—14OCT16
Batteries
1— Battery (2 used)
If one battery in a 24-volt system has malfunctioned
but the other is still good, replace the malfunctioned
battery with one of the same type. For example, replace
a malfunctioned maintenance-free battery with a new
maintenance-free battery. Different types of batteries
may have different rates of charge. This difference could
overload one of the batteries and cause it to malfunction.
4-1-8
112321
PN=268