Maintenance—Periodic Maintenance
KR46761,0001149 -19-26APR16-1/1
Prepare Machine for Maintenance
Before performing maintenance procedures in the
following chapters and before leaving operator's seat,
park machine as described below unless another position
is specied in the procedure.
1. Park machine on a level surface.
2. Lower equipment to the ground.
3. Turn auto-idle switch (1) to the A/I OFF position.
IMPORTANT: Turbocharger can be damaged
if procedure to shut down engine is
not done properly.
4. Run engine with engine speed dial (2) at 1/3 position
without load for 2 minutes.
5. Turn engine speed dial to slow idle position.
6. Turn key switch (3) to the OFF position. Remove key
from switch.
7. Place pilot shutoff lever (4) to locked (UP) position.
IMPORTANT: Avoid machine damage. After
turning key switch to OFF position, only turn
battery disconnect switch to OFF position when
indicator light (if equipped) no longer illuminates.
8. Turn battery disconnect switch to the OFF position.
See Battery Disconnect Switch. (Section 2-3.)
1— Auto-Idle Switch
2— Engine Speed Dial
3— Key Switch
4— Pilot Shutoff Lever