Maintenance—Every 500 Hours
KR46761,000124B -19-22AUG16-1/1
KR46761,00013CF -19-12OCT16-1/1
Check Cab Tilt Oil Level—Rear Entry Cab
Only
1. Park machine on a level surface.
CAUTION: Turbocharger can be damaged
if procedure to shut down engine is not
done properly.
2. Run engine at slow idle speed without load for 5
minutes.
3. Stop engine.
4. Open cab service door (1) to access the cab tilt
hydraulic pump.
5. Check oil level on the cab tilt oil tank (2). Oil level
must be at the FILL line.
6. If necessary, remove ll cap (3) and add oil. See Cab
Tilt Oil—Rear Entry Cab Only. (Section 3-1.)
7. Install ll cap.
8. Close cab service door.
1— Cab Service Door
2— Cab Tilt Oil Tank
3— Fill Cap
TX1213788 —UN—26APR16
Cab Service Door
TX1214902 —UN—18MAY16
Cab Tilt Hydraulic Pump
Clean Cooler Inlet Screen
CAUTION: Prevent possible injury from rotating
fan and ying debris. Shut off engine before
opening door. Avoid rotating fan and fan blast.
Clear area of bystanders and wear personal
protection equipment, including eye protection.
Reduce compressed air to less than 196 kPa (1.96
bar) (28.4 psi) when using for cleaning purposes.
1. Stop engine.
2. Open engine cover and left rear service door.
3. Release latches (1) and use handles (2) to remove
cooler inlet screen (3).
4. Attach an air wand to an air compressor and blow dirt
and debris from the cooler inlet screen.
5. Install cooler inlet screen and secure latches.
6. Close service door and engine cover.
TX1224929 —UN—29SEP16
Cooler Inlet Screen
1— Latch (3 used)
2— Handle (2 used)
3— Cooler Inlet Screen
3-9-3