Hitachi ZAXIS 260F-FE-6N

User Manual - Page 248

For ZAXIS 260F-FE-6N.

PDF File Manual, 383 pages, Download pdf file

Loading ...
Loading ...
Loading ...
Maintenance—Every 1000 Hours
KR46761,00013D9 -19-08NOV16-1/1
Replace Final Fuel Filter
1. Ensure key switch is in the OFF position.
2. Open right rear service door to access nal fuel lter
(1).
3. Thoroughly clean exterior of nal fuel lter and
surrounding area.
NOTE: Additional fuel will remain in the nal
fuel lter housing.
4. Remove nal fuel lter using a lter wrench. Dispose
of used lter properly.
5. Clean lter mounting base.
IMPORTANT: DO NOT prell fuel lters. Debris
in unltered fuel will damage fuel system
components.
Only lubricate lter seal with diesel fuel
before installing.
6. Install new nal fuel lter onto mounting base. Rotate
lter housing clockwise by hand. Tighten 1/2—3/4 turn
after seal contacts mounting base.
7. Prime fuel system and bleed air. See Bleed Fuel
System. (Section 4-1.)
8. Close service door.
TX1226144 —UN—13OCT16
Final Fuel Filter
1— Final Fuel Filter
3-10-7
112321
PN=246