Maintenance—Every 10 Hours or Daily
KR46761,00013AB -19-01DEC16-1/1
KR46761,00013AC -19-18OCT16-1/1
Drain Water and Sediment From Fuel Tank
Sump
1. Park machine on a level surface. Rotate
upperstructure 90° for easier access.
IMPORTANT: Turbocharger can be damaged
if procedure to shut down engine is
not done properly.
2. Run engine at slow idle speed without load for 5
minutes.
3. Stop engine.
4. Remove fuel tank ll cap.
5. Open right rear service door to access drain valve (1)
for the fuel tank.
6. Open drain valve for several seconds to drain water
and sediment into a suitable container. Dispose of
waste properly. Close drain valve.
TX1224475 —UN—26SEP16
Drain Valve
1— Drain Valve
7. Close service door and install fuel tank ll cap.
Drain Primary Fuel Filter and Water Separator
1. Open right rear service door to access primary fuel
lter and water separator (1).
2. Open drain valve (2) to extract water from fuel system.
Drain uid until water and sediment are removed into
suitable container. Dispose of waste properly.
3. Close drain valve.
4. Prime fuel system and bleed air. See Bleed Fuel
System. (Section 4-1.)
5. Close service door.
1— Primary Fuel Filter and
Water Separator
2— Drain Valve
TX1224477 —UN—13OCT16
Primary Fuel Filter and Water Separator
3-4-6
112321