Maintenance—As Required
JL41294,0000368 -19-26AUG21-1/1
Replace Case Drain Filter—If Equipped
1. Prepare machine for maintenance. See Prepare
Machine for Maintenance. (Section 3-2.)
2. Depressurize the hydraulic system. See Drain and
Rell Hydraulic Tank Oil and Clean Suction Screen.
(Section 3-15.)
3. Remove cap screws (1) and cover (2).
4. Turn lter bowl (3) counterclockwise, and remove from
head assembly (4).
5. Remove lter element from inside of bowl, and inspect
the surface for contamination.
6. Discard lter element.
7. Inspect lter head assembly for possible damage.
Replace as necessary.
8. Lubricate O-ring seal, and install new lter element.
9. Lightly lubricate the threads of the lter bowl and
O-ring, and screw the lter bowl into the head
assembly.
10. Install cover and cap screws.
11. Bleed air from hydraulic system. See Bleed Hydraulic
System. (Section 4-1.)
1— Cap Screw (4 used)
2— Cover
3— Filter Bowl
4— Head Assembly
TX1316153A —UN—26AUG21
Processor Boom Hydraulic Lines
TX1316155A —UN—26AUG21
High-Pressure Supply Filter and Case Drain Filter