Operation—Monitor Operation
KR46761,0001337 -19-02FEB17-2/31
KR46761,0001337 -19-02FEB17-3/31
KR46761,0001337 -19-02FEB17-4/31
KR46761,0001337 -19-02FEB17-5/31
KR46761,0001337 -19-02FEB17-6/31
Continued on next page KR46761,0001337 -19-02FEB17-7/31
Possible alarm indicators that could appear are:
•Aftertreatment Device Regeneration Request—If
the alarm indicator is illuminated yellow and blinking,
aftertreatment device is restricted and an aftertreatment
device regeneration should be performed. Immediately
move machine to safe area and perform an aftertreatment
device manual regeneration.
TX1086346 —UN—06JAN11
Aftertreatment Device Regeneration Request
Aftertreatment Device Regeneration Inhibit—Af-
tertreatment device regeneration inhibit is enabled and
aftertreatment device regeneration cannot be performed.
Move machine to safe area and release the aftertreatment
device regeneration inhibit.
TX1086347 —UN—06JAN11
Aftertreatment Device Regeneration Inhibit
Aftertreatment Device Regeneration System Error
Alarm—There is a system or hardware error causing
the aftertreatment device regeneration to abort. See an
authorized Hitachi dealer.
TX1086356 —UN—06JAN11
Aftertreatment Device Regeneration System Error Alarm
Engine Oil Level Alarm—Check engine oil level and
rell oil.
TX1086348 —UN—06JAN11
Engine Oil Level Alarm
Engine Oil Pressure Alarm—Engine oil pressure has
decreased. Immediately stop engine. Check engine oil
system and oil level.
TX1086353 —UN—06JAN11
Engine Oil Pressure Alarm
Engine Start Disabled Alarm—Engine will not start due
to pilot shutoff lever being lowered or engine stop switch
is in OFF position.
TX1086354 —UN—06JAN11
Engine Start Disabled Alarm