Hitachi ZAXIS 260F-FE-6N

User Manual - Page 246

For ZAXIS 260F-FE-6N.

PDF File Manual, 383 pages, Download pdf file

Loading ...
Loading ...
Loading ...
Maintenance—Every 1000 Hours
KR46761,0001417 -19-07NOV16-2/2
6. Open right rear service door to access pilot oil lter (6).
7. Remove lter canister (7) from head cover by turning
counterclockwise.
8. Clean head cover contact area.
9. Remove lter element (8) and O-ring (9).
10. Install new O-ring and lter element.
11. Install lter canister clockwise by hand. Check for any
leakage.
12. Close service door.
13. Install hydraulic tank cap (1) to case assembly (4)
using aligning marks (5) and turning cap clockwise
to lock position.
14. Bleed air from hydraulic system. See Bleed Hydraulic
System. (Section 4-1.)
1— Hydraulic Tank Cap
2— Hex Wrench
3— Hole
4— Case Assembly
5— Aligning Mark (2 used)
6— Pilot Oil Filter
7— Filter Canister
8— Filter Element
9— O-Ring
TX1217913 —UN—19JUL16
Pilot Oil Filter
8
7
9
TX1217707 —UN—22JUN16
Pilot Filter Assembly
1
4
3
2
5
TX1217692 —UN—22JUN16
Hydraulic Tank Cap
3-10-5
112321
PN=244
Loading ...
Loading ...
Loading ...