On-line preset (9 SYSTEM
7 ONLINE SETTING .......... PGM2)
(1) Select the PGM2 mode and touch the [2 POS SETTING] to perform the programming.
(2) Touch the [9 SYSTEM] button to display the menu, and touch the [7 ONLINE PRESET] button to
program.
(3) Touch the required program item, and enter each parameter and touch the [ENTER] key.
Repeat this step (3) satisfactorily.
(4) To terminate the programming, touch the [EXIT] key.
Text Parameter
CHANNEL# 0 5: 0 means no RS-232 channel is assigned.
TERMINAL No. 6 digits ((0 to 999999) : 000001)
CI SIGNAL
SENSING: Sensing of the CI signal
NON: Non sensing of the CI signal
Transmission line form;
LINE FORM HALF: Half duplex system
FULL: Full duplex system
Transmission data rate (Baud rate)
115200 bps
57600 bps
BAUD RATE
38400 bps
19200 bps
9600 bps
4800 bps
2400 bps
START CODE Start code: 3 digits ((0 to 127) : 002)
END CODE End code: 3 digits ((0 to 127) : 013)
TIME OUT Time out time: 3 digits ((1 to 255 (sec)) : 007)
AT COMMAND OPEN At command with open store: max. 50 characters (null)
AT COMMAND CLOSE At command with close store: max. 50 characters (null)