Siglent SDS1000CFL

SDS1000CFL User Manual - Page 44

For SDS1000CFL.

PDF File Manual, 134 pages, Download pdf file

Loading ...
Loading ...
Loading ...
SIGLENT
34 SDS1000CFL User Manual
2.8.1 Signal Source
You can use the Trigger Source options to select the signal that the oscilloscope
uses as a trigger. The source can be any signal connected to a channel BNC, to
the EXT TRIG BNC or the AC power line (available only with Edge triggers).
2.8.2 Trigger Type
The scopes have five trigger types: Edge, Video, Pulse, Slope, and
Alternative.
Edge Trigger
Use Edge triggering to trigger on the edge of the oscilloscope input signal at the
trigger threshold.
Table 2-14 Edge Trigger function Menu:
Option
Setting
Explain
Type Edge
With Edge highlighted, the rising or falling edge of
the input signal is used for the trigger.
CH1
CH2
CH3
CH4
Triggers on a channel whether or not the waveform
is displayed.
EXT
Does not display the trigger signal; the Ext option
uses the signal connected to the EXT TRIG
front-panel BNC and allows a trigger level range of
-1.2V to +1.2V.
EXT/5
Same as Ext option, but attenuates the signal by a
factor of five, and allows a trigger level range of +6V
to -6V.This extends the trigger level range.
Source
AC Line
This selection uses a signal derived from the power
line as the trigger source; trigger coupling is set to
DC and the trigger level to 0 volts.
Slope
Trigger on Rising edge of the trigger signal.
Trigger on Falling edge of the trigger signal.
Trigger on Rising edge and Falling edge of the
trigger signal.
Loading ...