SDS1000CFL User Manual 99
Picture2.13-19
To record waveforms, follow these steps:
1. Press the UTILITY button to enter “Utility menu”.
2. Press the “Next Page” option button to enter the third page of “Utility menu”.
3. Press the “Record” button to enter “Waveform Record Menu”.
4. Press the “Mode” option button to select “Record”.
5. Press the “Source” option button to select the input signal channel.
6. Select “Interval” option, turn the Univeral” knob to adjust time interval between
record frames.
7. Select “End Frame”, select the Universal” knob to adjust the max record
frame.
8. Press “ in “Operate”option to record waveform.
Play Back: Play back current record waveforms or saved record waveforms.
Table 2-64 Waveform play back function menu 1
Option Setting Instruction
Mode Play Back Set the Play Back function menu.
Operate
Run
Stop
Press to start playback playing.
Press to stop playing.
Play Mode
Set circular play mode.
Set single time play mode.
Interval
Set time interval between frames.
Next Page
Page 1/2 Enter the second page of Play Back menu.