Chapter 80 Networked AV Mode
XGS2220 Series User’s Guide
677
The following table describes the related labels in this screen.
80.35 VLAN Port Setup
Use this screen to configure the static VLAN (IEEE 802.1Q) settings on a port. Click SWITCHING > VLAN >
VLAN Port Setup to display the screen as shown.
Figure 545 SWITCHING > VLAN > VLAN Port Setup
Table 359 SWITCHING > VLAN > Static VLAN > Add/Edit
LABEL DESCRIPTION
Active Enable the switch button to activate the VLAN settings.
Name Enter a descriptive name for the VLAN group for identification purposes. This name consists of up
to 64 printable ASCII characters. The string should not contain [ ? ], [ | ], [ ' ], [ " ] or [ , ].
VLAN Group ID Enter the VLAN ID for this static entry; the valid range is between 1 and 4094.
Port The port number identifies the port you are configuring.
* Settings in this row apply to all ports.
Use this row only if you want to make some settings the same for all ports. Use this row first to set
the common settings and then make adjustments on a port-by-port basis.
Note: Changes in this row are copied to all the ports as soon as you make them.
Control Select Normal for the port to dynamically join this VLAN group using GVRP. This is the default
selection.
Select Fixed for the port to be a permanent member of this VLAN group.
Select Forbidden if you want to prohibit the port from joining this VLAN group.
Tagging Select Tx Tagging if you want the port to tag all outgoing frames transmitted with this VLAN
Group ID.
Apply Click Apply to save your changes to the Switch’s run-time memory. The Switch loses these
changes if it is turned off or loses power, so use the Save link on the top navigation panel to save
your changes to the non-volatile memory when you are done configuring.
Clear Click Clear to clear the fields to the factory defaults.
Cancel Click Cancel to not save the configuration you make and return to the last screen.