Chapter 80 Networked AV Mode
XGS2220 Series User’s Guide
633
80.7 SYSTEM
The following sections introduces the SYSTEM screens.
80.8 What You Can Do
Use the Cloud Management screen (Section 80.9 on page 634) to view NCC Connection status and
enable/disable NCC Discovery.
Use the General Setup screen (Section 80.10 on page 635) to configure general settings such as the
system name and time.
Use the IP Setup screen (Section 80.11 on page 637) to configure the default gateway device, the
default domain name server and add IP domains.
Use the Logins screen (Section 80.12 on page 639) to change the system password, configure
passwords for up to four users and set their privilege level.
Temperature
(C/F)
BOARD/MAC/PHY refers to the location of the temperature sensor on the Switch printed circuit
board.
Status This field displays Normal for temperatures below the threshold and Error for those above.
Current This shows the current temperature at this sensor.
MAX This field displays the maximum temperature measured at this sensor.
MIN This field displays the minimum temperature measured at this sensor.
Threshold This field displays the upper temperature limit at this sensor.
Fan Speed
(RPM)
A properly functioning fan is an essential component (along with a sufficiently ventilated, cool
operating environment) in order for the device to stay within the temperature threshold. Each
fan has a sensor that is capable of detecting and reporting if the fan speed falls below the
threshold shown.
Status Normal indicates that this fan is functioning above the minimum speed. Error indicates that this
fan is functioning below the minimum speed.
Current This field displays this fan's current speed in Revolutions Per Minute (RPM).
MAX This field displays this fan's maximum speed measured in Revolutions Per Minute (RPM).
MIN This field displays this fan's minimum speed measured in Revolutions Per Minute (RPM). "<41" is
displayed for speeds too small to measure (under 2000 RPM).
Threshold This field displays the minimum speed at which a normal fan should work.
Voltage(V) The power supply for each voltage has a sensor that is capable of detecting and reporting if the
voltage falls out of the tolerance range.
Status Normal indicates that the voltage is within an acceptable operating range at this point;
otherwise Error is displayed.
Current This is the current voltage reading.
MAX This field displays the maximum voltage measured at this point.
MIN This field displays the minimum voltage measured at this point.
Threshold This field displays the percentage tolerance of the voltage with which the Switch still works.
Table 329 MONITOR > System Information (continued)
LABEL DESCRIPTION