Rigol DS8034-R oscilloscope

Rigol DS8000 R manual - Page 147

For DS8034-R.

PDF File Manual, 346 pages, Read Online | Download pdf file

DS8034-R photo
Loading ...
Loading ...
Loading ...
Chapter 6 Operations and Measurements RIGOL
DS8000-R User Guide 6-19
enabled). The sample rate of the analog channel or the changes of the memory
depth can affect the Math sample rate.
⚫ Click More → AutoSetting to adjust the vertical scale and offset of the
operation results to an optimal value based on the current configuration, so as
to better observe.
⚫ Click More → Invert to enable or disable the inverted display function of the
waveform.
⚫ Click More → Label to set the label for math operation results. For details, refer
to descriptions in "Math Operation Label".
⚫ Click More → Color Grade to enable or disable the color grade display of the
operation results. When enabled, different colors are displayed on the screen to
indicate the times of data acquisition or acquisition probability.
⚫ Click More → Reset ColorGrade to clear the color grade display and display
the color grade again.
High Pass
Only allows the signals whose frequencies are higher than the current lower limit
frequency to pass.
Click Math → Math1 → Operator to select "HighPass":
âš« Click Operation continuously to enable or disable the "HighPass" operation
function.
âš« Click SourceA to select the channel for Source A. The available channels for
Source A are CH1-CH4 and Ref1-Ref10.
Note: The source of Math2 can be CH1-CH4, Ref1-Ref10, or Math1; the source
of Math3 can be CH1-CH4, Ref1-Ref10, Math1, or Math2; the source of Math4
can be CH1-CH4, Ref1-Ref10, Math1, Math2, or Math3; only the channels that
have been enabled currently can be selected.
âš« Click Offset to set the vertical offset of the operation results. For setting
methods, refer to the descriptions in "Parameter Setting Method".
âš« Click Scale to set the vertical scale of the operation results. For setting methods,
refer to the descriptions in "Parameter Setting Method".
⚫ Click ωc to set the lower limit frequency. For setting methods, refer to
descriptions in "Parameter Setting Method".
Note: The settable range of the lower limit frequency is related to the Math
sample rate (displayed at the bottom of the screen when the Math function is
enabled). The sample rate of the analog channel or the changes of the memory
depth can affect the Math sample rate.
⚫ Click More → AutoSetting to adjust the vertical scale and offset of the
operation results to an optimal value based on the current configuration, so as
to better observe.
Loading ...
Loading ...
Loading ...