Hardware conguration in AXIS Entry Manager
1. Go to AXIS Entry Manager and start a new hardware conguration under Setup.
2. In the hardware conguration, rename the network door controller to “Gate controller”.
3. Click Next.
4. In Congure locks connected to this controller, clear the Door monitor option.
5. Click Next.
6. In Congure readers connected to this controller, clear the Exit reader option.
7. Click Finish.
Conguration in AXIS License Plate Verier
1. Go the AXIS License Plate Verier webpage.
2. Go to the Settings > Access control.
3. Go to Type and select Controller in the drop-down list.
4. Enter the following information:
- the IP address for the controller in format 192.168.0.0
- the username for the controller
- the password for the controller
5. Click Connect.
6. If the connection is successful, “Gatecontroller” shows up in the Network Door Controller name drop-down list. Select
“Gatecontroller”.
7. In the Reader name drop-down list, select the reader connected to the door “Gatecontroller”, for example “Reader
entrance”. These names can be changed in AXIS Entry Manager.
8. To activate the connection, select Turn on integration.
9. Enter one of the user’s license plate number, or use the default, in the test eld and click Test integration. Check that the
test was successful.
Congure users, groups, doors, and schedules in AXIS Entry Manager
1. Go to AXIS Entry Manager.
2. Go to Access Management.
3. Go to Doors > Add identication type.