Installation
*INSTALLATION*
112
Electrical connection: Other
countries
All electrical work should be carried out
by a suitably qualified and competent
Miele approved service technician in
strict accordance with local and
national safety regulations.
The voltage and rated load are given on
the data plate situated at the front of
the oven interior. Please ensure that
these match the household mains
supply.
Connection should be made via a fused
connection unit or a suitable isolator,
which complies with national and local
safety regulations, and the on/off switch
should be easily accessible after the
appliance has been installed.
If the switch is not accessible after
installation (depending on country) an
additional means of disconnection must
be provided for all poles.
Switches with a minimum all-pole
contact gap of 3mm are suitable for
isolating the appliance. These include
circuit breakers, fuses and protective
devices.
For extra safety it is advisable to install
a suitable residual current device
(RCD) / ground fault interrupter (GFI).
Contact a qualified electrician for
advice.
If the cord is damaged a new cord must
be fitted by a Miele approved service
technician.
WARNING - THIS APPLIANCE
MUST BE EARTHED
Hong Kong
This appliance is supplied with a power
cord for connection to mains electricity
supply.
Taiwan
This appliance is supplied with a power
cord for connection to mains electricity
supply.
Temporary or permanent operation on
an autonomous power supply system or
a power supply system that is not
synchronised with the mains power
supply (e.g. island networks, back-up
systems) is possible. A prerequisite for
operation is that the power supply
system complies with the specifications
of EN50160 or an equivalent standard.
The function and operation of the
protective measures provided in the
domestic electrical installation and in
this Miele product must also be
maintained in isolated operation or in
operation that is not synchronised with
the mains power supply, or these
measures must be replaced by
equivalent measures in the installation.
As described, for example, in the
current version of
BS OHSAS 18001–2 ISO 45001.