Help Guide - Page 85

For FDR-AX700.

Loading ...
Loading ...
Loading ...
GAMMA:
Select a gamma curve.
STANDARD: Standard gamma curve for movies
STILL: Gamma curve like an interchangeable-lens still camera movie.
CINE1: Makes soft color images by decreasing dark area contrast and sharpening bright area tone changes
(equivalent to HG4609G33 ).
CINE2: Almost the same effect as [CINE1]; select this if you want to treat the image in a range within 100% of video
signal when editing, etc. (equivalent to HG4600G30).
CINE3: Increases contrast between bright areas and dark areas more than those of [CINE1] and [CINE2],
sharpening dark area tone changes.
CINE4: Increases dark area contrast more than that of [CINE3]. The dark area contrast is weaker and the bright area
contrast is stronger than that of [STANDARD].
ITU709: Gamma curve that corresponds to ITU-709. Gain in low intensity area: 4.5
ITU709(800%): Gamma curve for checking scenes when shooting using [S-LOG2] or [S-LOG3].
S-LOG2: [S-LOG2] gamma curve. This setting presumes editing in post-production after shooting.
S-LOG3: [S-LOG3] gamma curve. Gamma curve with characteristics similar to film, and which presumes editing in
post-production after shooting.
HLG: Gamma curve for HDR recording that corresponds to ITU-R BT.2100.
HLG1: Gamma curve for HDR recording. In this setting, reduction of the noise level takes priority, but dynamic range
for shooting is narrower than that of [HLG2] or [HLG3].
HLG2: Gamma curve for HDR recording. This setting considers the balance between dynamic range and noise.
HLG3: Gamma curve for HDR recording. Dynamic range is wider than that of [HLG2] but the noise level is higher.
[HLG1], [HLG2], or [HLG3] is gamma curve with same characteristics whose balance between dynamic range and
noise are different. Maximum video output level value of each differs as follows:
[HLG1]: approx. 87%, [HLG2]: approx. 95%, [HLG3]: approx. 100%
BLACK GAMMA:
Corrects gamma in low intensity area.
When [HLG], [HLG1], [HLG2] or [HLG3] is selected for [GAMMA], [BLACK GAMMA] is disabled.
RANGE: Select a correcting range.
HIGH/MIDDLE/LOW
LEVEL: Select a correcting level.
‒7 (maximum black compression) to +7 (maximum black stretch)
KNEE:
Sets the knee point and slope for video signal compression to prevent over-exposure by limiting signals in high intensity
areas of the subject to the dynamic range of the camcorder.
When [CINE1], [CINE2], [CINE3], [CINE4], [STILL], [ITU709(800%)], [S-LOG2], [S-LOG3], [HLG], [HLG1], [HLG2], or
[HLG3] is selected in [GAMMA], [KNEE] is disabled if [MODE] is set to [AUTO]. To use functions in [KNEE], set [MODE]
to [MANUAL].
MODE: Select automatic or manual mode.
AUTO: Sets the knee point and slope automatically.
MANUAL: Sets the knee point and slope manually.
AUTO SET: Set the maximum point and sensitivity in [AUTO] mode.
MAX POINT: Sets the maximum value of the knee point.
90.0% to 100.0%
SENSITIVITY: Sets the sensitivity.
HIGH/SENSITIVITY/LOW
MANUAL SET : Set the knee point and slope in [MANUAL] mode.
POINT: Set the knee point.
75.0% to 105.0%