8. Power, Environment and Digital I/O
Serial and network-connected UPS systems must first be connected to and configured to communicate with the console
server:
• For serial UPS systems, attach the UPS to the selected serial port on the console server. From the Serial and Network:
Serial Port menu, configure the Common Settings of that port with the RS-232 properties required by the UPS (refer to
4.1.1 Common Settings). Select UPS as the Device Type.
• Similarly, for each network-connected UPS, go to Serial & Network: Network Hosts menu and configure the UPS as a
connected host by specifying it as Device Type: UPS. Click Apply.
• No such configuration is required for USB-connected UPS hardware.
• Select the Serial & Network: UPS Connections menu. The Managed UPS section will display all UPS connections that
have already been configured.
• Click Add Managed UPS.
• Select if the UPS will be Connected Via USB, over preconfigured serial port or SNMP/HTTP/HTTPS over the preconfigured
network host connection.